Quantum yield

From testwiki
Jump to navigation Jump to search

Template:Short description

In particle physics, the quantum yield (denoted Template:Math) of a radiation-induced process is the number of times a specific event occurs per photon absorbed by the system.[1]

Φ(λ)= number of events  number of photons absorbed 

Applications

Fluorescence spectroscopy

The fluorescence quantum yield is defined as the ratio of the number of photons emitted to the number of photons absorbed.[2]

Φ=# photons emitted# photons absorbed

Fluorescence quantum yield is measured on a scale from 0 to 1.0, but is often represented as a percentage. A quantum yield of 1.0 (100%) describes a process where each photon absorbed results in a photon emitted. Substances with the largest quantum yields, such as rhodamines, display the brightest emissions; however, compounds with quantum yields of 0.10 are still considered quite fluorescent.

Quantum yield is defined by the fraction of excited state fluorophores that decay through fluorescence:

Φf=kfkf+knr

where

  • Template:Math is the fluorescence quantum yield,
  • Template:Mvar is the rate constant for radiative relaxation (fluorescence),
  • Template:Math is the rate constant for all non-radiative relaxation processes.

Non-radiative processes are excited state decay mechanisms other than photon emission, which include: Förster resonance energy transfer, internal conversion, external conversion, and intersystem crossing. Thus, the fluorescence quantum yield is affected if the rate of any non-radiative pathway changes. The quantum yield can be close to unity if the non-radiative decay rate is much smaller than the rate of radiative decay, that is Template:Math.[2]

Fluorescence quantum yields are measured by comparison to a standard of known quantum yield.[2] The quinine salt quinine sulfate in a sulfuric acid solution was regarded as the most common fluorescence standard,[3] however, a recent study revealed that the fluorescence quantum yield of this solution is strongly affected by the temperature, and should no longer be used as the standard solution. The quinine in 0.1M perchloric acid (Template:Math 0.60) shows no temperature dependence up to 45 °C, therefore it can be considered as a reliable standard solution.[4]

Fluorescence quantum yield standards
Compound Solvent λex(nm) Φ
Quinine 0.1 M Template:Chem2 347.5 0.60 ± 0.02
Fluorescein 0.1 M Template:Chem2 496 0.95 ± 0.03
Tryptophan Water 280 0.13 ± 0.01
Rhodamine 6G Ethanol 488 0.94

Experimentally, relative fluorescence quantum yields can be determined by measuring fluorescence of a fluorophore of known quantum yield with the same experimental parameters (excitation wavelength, slit widths, photomultiplier voltage etc.) as the substance in question. The quantum yield is then calculated by:

Φ=ΦR×𝐼𝑛𝑡𝐼𝑛𝑡R×110AR110A×n2nR2

where

The subscript Template:Math denotes the respective values of the reference substance.[5][6] The determination of fluorescence quantum yields in scattering media requires additional considerations and corrections.[7]

FRET efficiency

Förster resonance energy transfer efficiency (Template:Mvar) is the quantum yield of the energy-transfer transition, i.e. the probability of the energy-transfer event occurring per donor excitation event:

E=ΦFRET=kETkET+kf+knr

where

  • Template:Math is the rate of energy transfer,
  • Template:Mvar the radiative decay rate (fluorescence) of the donor,
  • Template:Math are non-radiative relaxation rates (e.g., internal conversion, intersystem crossing, external conversion etc.).[8][9]

Solvent and environmental effects

A fluorophore's environment can impact quantum yield, usually resulting from changes in the rates of non-radiative decay.[2] Many fluorophores used to label macromolecules are sensitive to solvent polarity. The class of 8-anilinonaphthalene-1-sulfonic acid (ANS) probe molecules are essentially non-fluorescent when in aqueous solution, but become highly fluorescent in nonpolar solvents or when bound to proteins and membranes. The quantum yield of ANS is ~0.002 in aqueous buffer, but near 0.4 when bound to serum albumin.

Photochemical reactions

The quantum yield of a photochemical reaction describes the number of molecules undergoing a photochemical event per absorbed photon:[1]

Φ=# molecules undergoing reaction of interest# photons absorbed by photoreactive substance

In a chemical photodegradation process, when a molecule dissociates after absorbing a light quantum, the quantum yield is the number of destroyed molecules divided by the number of photons absorbed by the system. Since not all photons are absorbed productively, the typical quantum yield will be less than 1.

Φ=# molecules decomposed# photons absorbed

Quantum yields greater than 1 are possible for photo-induced or radiation-induced chain reactions, in which a single photon may trigger a long chain of transformations. One example is the reaction of hydrogen with chlorine, in which as many as 106 molecules of hydrogen chloride can be formed per quantum of blue light absorbed.[10]

Quantum yields of photochemical reactions can be highly dependent on the structure, proximity and concentration of the reactive chromophores, the type of solvent environment as well as the wavelength of the incident light. Such effects can be studied with wavelength-tunable lasers and the resulting quantum yield data can help predict conversion and selectivity of photochemical reactions.[11]

In optical spectroscopy, the quantum yield is the probability that a given quantum state is formed from the system initially prepared in some other quantum state. For example, a singlet to triplet transition quantum yield is the fraction of molecules that, after being photoexcited into a singlet state, cross over to the triplet state.

Photosynthesis

Quantum yield is used in modeling photosynthesis:[12]

Φ=μmol CO2 fixedμmol photons absorbed

See also

References

Template:Reflist

  1. 1.0 1.1 Template:Cite journal
  2. 2.0 2.1 2.2 2.3 Lakowicz, Joseph R. Principles of Fluorescence Spectroscopy (Kluwer Academic / Plenum Publishers 1999) p.10. Template:ISBN
  3. Template:Cite journal
  4. Template:Cite journal
  5. Albert M. Brouwer, Standards for photoluminescence quantum yield measurements in solution (IUPAC Technical Report), Pure Appl. Chem., Vol. 83, No. 12, pp. 2213–2228, 2011. doi:10.1351/PAC-REP-10-09-31.
  6. Template:Cite journal
  7. Template:Cite journal
  8. Template:Cite journal
  9. Template:Cite web
  10. Laidler K.J., Chemical Kinetics (3rd ed., Harper & Row 1987) p.289 Template:ISBN
  11. Template:Cite journal
  12. Template:Cite journal