Normalized frequency (signal processing)

From testwiki
Jump to navigation Jump to search

Template:Short description

In digital signal processing (DSP), a normalized frequency is a ratio of a variable frequency (f) and a constant frequency associated with a system (such as a sampling rate, fs). Some software applications require normalized inputs and produce normalized outputs, which can be re-scaled to physical units when necessary. Mathematical derivations are usually done in normalized units, relevant to a wide range of applications.

Examples of normalization

A typical choice of characteristic frequency is the sampling rate (fs) that is used to create the digital signal from a continuous one. The normalized quantity, f=ffs, has the unit cycle per sample regardless of whether the original signal is a function of time or distance. For example, when f is expressed in Hz (cycles per second), fs is expressed in samples per second.[1]

Some programs (such as MATLAB toolboxes) that design filters with real-valued coefficients prefer the Nyquist frequency (fs/2) as the frequency reference, which changes the numeric range that represents frequencies of interest from [0,12] cycle/sample to [0,1] half-cycle/sample. Therefore, the normalized frequency unit is important when converting normalized results into physical units.

Example of plotting samples of a frequency distribution in the unit "bins", which are integer values. A scale factor of 0.7812 converts a bin number into the corresponding physical unit (hertz).

A common practice is to sample the frequency spectrum of the sampled data at frequency intervals of fsN, for some arbitrary integer N (see Template:Slink). The samples (sometimes called frequency bins) are numbered consecutively, corresponding to a frequency normalization by fsN.[2]Template:Rp[3] The normalized Nyquist frequency is N2 with the unit Template:Sfracth cycle/sample.

Angular frequency, denoted by ω and with the unit radians per second, can be similarly normalized. When ω is normalized with reference to the sampling rate as ω=ωfs, the normalized Nyquist angular frequency is Template:Nowrap.

The following table shows examples of normalized frequency for f=1 kHz, fs=44100 samples/second (often denoted by 44.1 kHz), and 4 normalization conventions:

Quantity Numeric range Calculation Reverse
f=ffs   Template:Math0, Template:SfracTemplate:Math cycle/sample 1000 / 44100 = 0.02268 f=ffs
f=ffs/2   [0, 1] half-cycle/sample 1000 / 22050 = 0.04535 f=ffs2
f=ffs/N   Template:Math0, Template:SfracTemplate:Math bins 1000 × Template:Mvar / 44100 = 0.02268 Template:Mvar f=ffsN
ω=ωfs   [0, πradians/sample 1000 × 2π / 44100 = 0.14250 ω=ωfs

See also

References

Template:Reflist

  1. Cite error: Invalid <ref> tag; no text was provided for refs named Carlson
  2. Cite error: Invalid <ref> tag; no text was provided for refs named Harris
  3. Cite error: Invalid <ref> tag; no text was provided for refs named Taboga