Luminous efficiency function

From testwiki
Jump to navigation Jump to search

Template:Short description Template:For

File:Luminosity.svg
Photopic (black) and scotopic (green) luminous efficiency functions.[c 1] The photopic includes the CIE 1931 standard[c 2] (solid), the Judd–Vos 1978 modified data[c 3] (dashed), and the Sharpe, Stockman, Jagla & Jägle 2005 data[c 4] (dotted). The horizontal axis is wavelength in nm.

A luminous efficiency function or luminosity function represents the average spectral sensitivity of human visual perception of light. It is based on subjective judgements of which of a pair of different-colored lights is brighter, to describe relative sensitivity to light of different wavelengths. It is not an absolute reference to any particular individual, but is a standard observer representation of visual sensitivity of a theoretical human eye. It is valuable as a baseline for experimental purposes, and in colorimetry. Different luminous efficiency functions apply under different lighting conditions, varying from photopic in brightly lit conditions through mesopic to scotopic under low lighting conditions. When not specified, the luminous efficiency function generally refers to the photopic luminous efficiency function.

The CIE photopic luminous efficiency function Template:Math or Template:Math is a standard function established by the Commission Internationale de l'Éclairage (CIE) and standardized in collaboration with the ISO, [1] and may be used to convert radiant energy into luminous (i.e., visible) energy. It also forms the central color matching function in the CIE 1931 color space.

Details

File:Fluorescence in beer @ 450nm illumination.jpg
Fluorescence in beer. The one watt laser appears much dimmer than the fluorescence it produces, because the camera, like the human eye, is much more sensitive between 500 and 600 nm than at the laser's 450 nm wavelength.

There are two luminous efficiency functions in common use. For everyday light levels, the photopic luminosity function best approximates the response of the human eye. For low light levels, the response of the human eye changes, and the scotopic curve applies. The photopic curve is the CIE standard curve used in the CIE 1931 color space.

The luminous flux (or visible power) in a light source is defined by the photopic luminosity function. The following equation calculates the total luminous flux in a source of light:

Φv=683.002 (lm/W)0y(λ)Φe,λ(λ)dλ,

where

Formally, the integral is the inner product of the luminosity function with the spectral power distribution.[2] In practice, the integral is replaced by a sum over discrete wavelengths for which tabulated values of the luminous efficiency function are available. The CIE distributes standard tables with luminosity function values at Template:Nowrap intervals from Template:Nowrap to Template:Nowrap.[cie 1]

The standard luminous efficiency function is normalized to a peak value of unity at Template:Nowrap (see luminous coefficient). The value of the constant in front of the integral is usually rounded off to Template:Val. The small excess fractional value comes from the slight mismatch between the definition of the lumen and the peak of the luminosity function. The lumen is defined to be unity for a radiant energy of Template:Nowrap at a frequency of Template:Nowrap, which corresponds to a standard air wavelength of Template:Nowrap rather than Template:Val, which is the peak of the luminosity curve. The value of Template:Overline(λ) is Template:Val at Template:Val, so that a value of 683/Template:Val = 683.002 is the multiplicative constant.[3]

The number 683 is connected to the modern (1979) definition of the candela, the unit of luminous intensity.[cie 2] This arbitrary number made the new definition give numbers equivalent to those from the old definition of the candela.

Improvements to the standard

The CIE 1924 photopic V(λ) luminosity function,[cie 3] which is included in the CIE 1931 color-matching functions as the Template:Overline(λ) function, has long been acknowledged to underestimate the contribution of the blue end of the spectrum to perceived luminance. There have been numerous attempts to improve the standard function, to make it more representative of human vision. Judd in 1951,[4] improved by Vos in 1978,[5] resulted in a function known as CIE VM(λ).[6] More recently, Sharpe, Stockman, Jagla & Jägle (2005) developed a function consistent with the Stockman & Sharpe cone fundamentals;[7] their curves are plotted in the figure above.

Stockman & Sharpe has subsequently produced an improved function in 2011, taking into account the effects of chromatic adaptation under daylight.[8] Their work in 2008[9] has revealed that "luminous efficiency or V(l) functions change dramatically with chromatic adaptation".[10]

ISO standard

The ISO standard is ISO/CIE FDIS 11664-1. The standard provides an incremental table by nm of each value in the visible range for the CIE 1924 function.[11][12]

Scotopic luminosity

For very low levels of intensity (scotopic vision), the sensitivity of the eye is mediated by rods, not cones, and shifts toward the violet, peaking around Template:Nowrap for young eyes; the sensitivity is equivalent to Template:Val[13] or Template:Val[14] at this peak. The standard scotopic luminous efficiency function or VTemplate:′(λ) was adopted by the CIE in 1951, based on measurements by Wald (1945) and by Crawford (1949).[15]

Luminosity for mesopic vision, a wide transitioning band between scotopic and phototic vision, is more poorly standardized. The consensus is that this luminous efficiency can be written as a weighted average of scotopic and mesopic luminosities, but different organizations provide different weighting factors.[16]

Color blindness

Protanopic (red, dotted) and deuteranopic (green, dashed) luminosity functions.[17] For comparison, the standard photopic curve is shown (black, solid).

Color blindness changes the sensitivity of the eye as a function of wavelength. For people with protanopia, the peak of the eye's response is shifted toward the short-wave part of the spectrum (approximately 540 nm), while for people with deuteranopia, there is a slight shift in the peak of the spectrum, to about 560 nm.[17] People with protanopia have essentially no sensitivity to light of wavelengths more than 670 nm.

Most non-primate mammals have the same luminous efficiency function as people with protanopia. Their insensitivity to long-wavelength red light makes it possible to use such illumination while studying the nocturnal life of animals.[18]

For older people with normal color vision, the crystalline lens may become slightly yellow due to cataracts, which moves the maximum of sensitivity to the red part of the spectrum and narrows the range of perceived wavelengths.Template:Citation needed

See also

References

Template:Reflist

CIE documents

Template:Reflist

Curve data

Template:Reflist

Template:Authority control


Cite error: <ref> tags exist for a group named "c", but no corresponding <references group="c"/> tag was found

  1. Template:Cite book
  2. Cite error: Invalid <ref> tag; no text was provided for refs named Charles2003
  3. Cite error: Invalid <ref> tag; no text was provided for refs named Wyszecki2000
  4. Cite error: Invalid <ref> tag; no text was provided for refs named Judd1975
  5. Cite error: Invalid <ref> tag; no text was provided for refs named Vos1978
  6. Cite error: Invalid <ref> tag; no text was provided for refs named Stiles1955
  7. Cite error: Invalid <ref> tag; no text was provided for refs named Sharpe2005
  8. Template:Cite journal
  9. Template:Cite journal
  10. Template:Cite journal
  11. Template:Cite web
  12. Template:Cite web
  13. Cite error: Invalid <ref> tag; no text was provided for refs named Kohei2004
  14. Cite error: Invalid <ref> tag; no text was provided for refs named Casimer1998
  15. Template:Cite web
  16. Photopic and Scotopic lumens - 4: When the photopic lumen fails us
  17. 17.0 17.1 Template:Cite book
  18. Template:Cite journalTemplate:Dead link


Cite error: <ref> tags exist for a group named "cie", but no corresponding <references group="cie"/> tag was found