Heat loss due to linear thermal bridging

From testwiki
Jump to navigation Jump to search

Template:Short description The heat loss due to linear thermal bridging (HTB) is a physical quantity used when calculating the energy performance of buildings. It appears in both United Kingdom[1] and Irish[2] methodologies.

Calculation

The calculation of the heat loss due to linear thermal bridging is relatively simple, given by the formula below:[3]

HTB=yAexp

In the formula, y=0.08 if Accredited Construction details used, and y=0.15 otherwise, and Aexp is the sum of all the exposed areas of the building envelope,

References