Arden Buck equation
Jump to navigation
Jump to search
The Arden Buck equations are a group of empirical correlations that relate the saturation vapor pressure to temperature for moist air. The curve fits have been optimized for more accuracy than the Goff–Gratch equation in the range Template:Convert.[1]
A set of several equations were developed, each of which is applicable in a different situation.
Formula
The equations suggested by Template:Harvtxt (which are modifications of the equations in Template:Harvtxt) are:
- , over liquid water, Template:Mvar > 0 °C
- , over ice, Template:Mvar < 0 °C
where:
- Template:Math is the saturation vapor pressure in hPa
- Template:Math is the exponential function
- Template:Mvar is the air temperature in degrees Celsius
Buck (1981) also lists enhancement factors for a temperature range of −80 to 50 °C (−112 to 122 °F) at pressures of 1,000 mb, 500 mb, and 250 mb. These coefficients are listed in the table below.
| °C | 1,000 mb | 500 mb | 250 mb |
|---|---|---|---|
| -80 | 1.00410 | 1.00200 | |
| -70 | 1.00360 | 1.00180 | |
| -60 | 1.00640 | 1.00320 | 1.00160 |
| -50 | 1.00580 | 1.00290 | 1.00140 |
| -40 | 1.00520 | 1.00260 | 1.00130 |
| -30 | 1.00470 | 1.00240 | 1.00120 |
| -20 | 1.00440 | 1.00220 | 1.00120 |
| -10 | 1.00410 | 1.00220 | 1.00120 |
| 0 | 1.00395 | 1.00219 | 1.00132 |
| 10 | 1.00388 | 1.00229 | |
| 20 | 1.00400 | 1.00251 | |
| 30 | 1.00426 | 1.00284 | |
| 40 | 1.00467 | 1.00323 | |
| 50 | 1.00519 |
See also
Notes
References
External links
- Web Page listing various vapor pressure equations (for below 0 °C)
- ↑ Buck 1981