Search results
Jump to navigation
Jump to search
- :<math> d </math> is the distance from the radiator in meters ...tion]] caused by objects around the transmitter or receiver may affect the electrical field strength considerably. ...3 KB (514 words) - 02:15, 20 November 2024
- ...ffect of [[parasitic element (electrical networks)|parasitic elements]] ([[electrical resistance|resistance]], [[capacitance]], and [[inductance]]), [[skin effec ...ter|meter]] tampering and bypassing, arranged false meter readings, faulty meters, and un-metered supply. Non-technical losses are reported to account for up ...4 KB (492 words) - 22:13, 13 August 2023
- ...ields]] that are performed using particular sensors or probes, such as EMF meters. These probes can be generally considered as [[Antenna (radio)|''antennas'' ==Meters== ...8 KB (1,223 words) - 21:55, 20 February 2024
- '''Concrete electrical resistivity''' can be obtained by applying a current into the concrete and ...two electrodes attached to the ends of a uniform cross-section specimen. Electrical resistivity is obtained from the equation:<ref name="McCarter_2009"/> ...9 KB (1,270 words) - 08:32, 3 August 2024
- ...netic field (i.e. a [[magnet]]) travels some distance through or past an [[electrical conductor]] (or vice versa). *[[Electricity meter#Electromechanical|Electricity meters]] ...3 KB (409 words) - 16:17, 17 December 2024
- {{About|the measuring instrument|the electrical component|Potentiometer}} This null balance measuring method is still important in electrical [[metrology]] and standards work and is also used in other areas of electro ...9 KB (1,424 words) - 06:27, 10 July 2024
- {{Short description|Electrical issue from unintended contact}} ...ossed wires Daniel Case edit.jpg|thumb|right| Short circuit in an overhead electrical distribution line]] ...8 KB (1,130 words) - 16:39, 16 September 2024
- The MKER-800 has an electrical generation capacity of 800 [[watt|MW]]. An automated process control system The MKER-1000 has a thermal power output of 3000 [[MWth]] and an electrical output of 1,068 MW. There are four circuits and 1,832 fuel elements in the ...8 KB (1,221 words) - 01:50, 18 October 2024
- ...convert the pressure variations to a flow sensor signal, in the form of an electrical signal; and a signal processor operable to receive the flow sensor signal a [[Category:Flow meters]] ...3 KB (513 words) - 11:00, 20 September 2024
- * Analog volt meters or d'Arsonval movements, which consist of a coil and a [[permanent magnet]] * The quadrant to which the actuator will point. This defines the [[Electrical polarity|polarity]] of the [[voltage]] to the sin coil and the cos coil. ...3 KB (527 words) - 15:25, 29 April 2023
- ...he MET to create thrust, it must go through a 4 step process of converting electrical energy into heat energy. # The microwave [[Electric field|electrical field]] causes the electrons to speed up, which then causes them to have co ...9 KB (1,434 words) - 23:07, 7 November 2024
- {{Short description|Constants describing characteristics of electrical motors}} ...rce|back EMF]] constant''') are values used to describe characteristics of electrical motors. ...15 KB (2,525 words) - 02:45, 2 February 2025
- ...Alternating current|a.c.]] It can be designed to work in terms of either [[Electrical impedance|impedance]] or [[admittance]]. It can be used on resistors, capac This bridge measures [[Electrical conductance|conductance]] and [[susceptance]] in parallel. The susceptance ...10 KB (1,586 words) - 08:47, 19 May 2024
- ...ective placement of instrumentation, such as fluid [[Flow measurement|flow meters]].<ref name=":3">{{Cite book|title=Mechanical Engineer's Handbook|last=Marg An example can be a pipe entirely covered by an electrical heating pad with the flow being introduced after a uniform heat flux from t ...19 KB (2,955 words) - 10:33, 29 November 2024
- Inductive power transfer (IPT) uses a magnetic field to transfer electrical energy without contact. Alternatively, a wheel with a motor on the carrier, ...mes No. Of Cells Per Carrier \times Efficiency Factor}\over Carrier Pitch (Meters)</math> ...9 KB (1,356 words) - 11:49, 26 February 2025
- ...ed to link in well with offshore wind platforms and their issues caused by electrical production fluctuations. It works by water flowing into a container, at sig ...ollow sphere and the surrounding sea, which is about 75 bar (≈1 bar per 10 meters).<ref name=":2" /> ...20 KB (2,920 words) - 14:42, 18 December 2024
- ...cal Oceanography</ref> and it has been used for benchmarking other current meters.<ref>Dickey, T. D., A. J. Plueddemann, and R. A. Weller, 1998: [http://www. The innovation brought from VMCM over other current meters results from the choice of the biaxial propeller sensors, developed with ac ...13 KB (2,073 words) - 06:17, 31 July 2024
- ...This pressure is equivalent to a column of water ([[hydraulic head]]) 270 meters high.<ref>[http://www.statkraft.com/energy-sources/osmotic-power/default.as ...| hdl =1721.1/103172|hdl-access=free }}</ref> A significant portion of the electrical power generated by PRO must be used by the pumps that circulate water throu ...12 KB (1,567 words) - 05:53, 25 January 2025
- ...s, a number of other parameters including [[reflection coefficient]] and [[electrical impedance]]. A precision variable [[Attenuator (electronics)|attenuator]] ...measurements done by more expensive equipment such as [[Network analyzer (electrical)|network analysers]]. However, slotted line measurement techniques are mor ...20 KB (3,095 words) - 15:25, 17 March 2023
- Due to the thermoelectric effect, the temperature difference causes an electrical voltage to build up within each thermocouple. This output voltage is direct === Power meters === ...19 KB (2,799 words) - 08:41, 19 May 2024