File:IT-earthing.svg

From testwiki
Jump to navigation Jump to search
Original file (SVG file, nominally 420 × 360 pixels, file size: 21 KB)
Render this image in .

This file is from Wikimedia Commons and may be used by other projects. The description on its file description page there is shown below.

Summary

Description
English: Circuit diagram of the concept of the IT earthing system. Note that this is not intended to show regional connection details.
Date
Source Own work
Author DiscreetParrot
Other versions

New design based on the original public domain image that was created and uploaded by Markus Kuhn. This adds a neutral connection, which may be provided in an IT system and was missing for no good reason in the original.

Interpretation

This diagram represents one of the earthing system arrangements defined by the IEC 60364-1 standard.

Only the three-phase four-wire conductor arrangement is shown. It should be understood that not all installations will have a connection to every distribution conductor, and not all distribution systems will include all conductors depicted (three-phase three-wire cases for example will not include a neutral).

To give a broad overview of the diagram: The box at the top-left, as labelled, represents a generator or transformer, with the curved lines depicting transformer coils. The horizontal lines at the top represent the distribution system. The vertical lines coming down from them represent the supply connection to an individual property/installation. The dashed box with the label 'Consumer installation' beneath it represents an individual property/building and its electrical installation as a whole. The set of 'dots' (connection points) just within the dashed box represent where the external supply has entered the property and is connected to the installation. (The dot on the far right in the TT and TN systems is the 'main earthing terminal'). The solid box labelled 'Equipment' represents an example item of equipment within the installation. This equipment includes items such as sockets and light fittings, along with appliances ('loads') of either 'fixed' nature (e.g. shower; cooker; boiler; machinery), or more portable and pluggable nature (e.g. hair dryer; kettle; television). (Note that in the TN-C system case the link between neutral and earth would likely take place at a socket rather than in each appliance).

Licensing

I, the copyright holder of this work, hereby publish it under the following license:
Creative Commons CC-Zero This file is made available under the Creative Commons CC0 1.0 Universal Public Domain Dedication.
The person who associated a work with this deed has dedicated the work to the public domain by waiving all of their rights to the work worldwide under copyright law, including all related and neighboring rights, to the extent allowed by law. You can copy, modify, distribute and perform the work, even for commercial purposes, all without asking permission.

 This vector image was created with Inkscape, and then manually edited.
Translate this file This SVG file contains embedded text that can be translated into your language, using any capable SVG editor, text editor or the SVG Translate tool. For more information see: About translating SVG files.

Captions

Circuit diagram of an IT earthing system

Items portrayed in this file

depicts

1 January 2025

image/svg+xml

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current14:44, 17 January 2026Thumbnail for version as of 14:44, 17 January 2026420 × 360 (21 KB)wikimediacommons>DiscreetParrottranslation of equipment improved, partly from IEC 60050; double word fixed in Russian translation; resistance replacd with impedance to better match standards; transformer capitalised; embedded description