Degree of reaction

From testwiki
Revision as of 07:23, 22 September 2024 by imported>OlliverWithDoubleL (short description, links, removed redundant sentence, block display)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Template:Short description Template:Use dmy dates

In turbomachinery, degree of reaction or reaction ratio (denoted Template:Mvar) is defined as the ratio of the change in static pressure in the rotating blades of a compressor or turbine, to the static pressure change in the compressor or turbine stage. Alternatively it is the ratio of static enthalpy change in the rotor to the static enthalpy change in the stage.

Various definitions exist in terms of enthalpies, pressures or flow geometry of the device. In case of turbines, both impulse and reaction machines, degree of reaction is defined as the ratio of energy transfer by the change in static head to the total energy transfer in the rotor:[1] R=Isentropic enthalpy change in rotorIsentropic enthalpy change in stage

For a gas turbine or compressor it is defined as the ratio of isentropic heat drop in the moving blades (the rotor) to the sum of the isentropic heat drops in both the fixed blades (the stator) and the moving blades: R=Isentropic heat drop in rotorIsentropic heat drop in stage

In pumps, degree of reaction deals in static and dynamic head. Degree of reaction is defined as the fraction of energy transfer by change in static head to the total energy transfer in the rotor: R=Static pressure rise in rotorTotal pressure rise in stage

Relation

Most turbo machines are efficient to a certain degree and can be approximated to undergo isentropic process in the stage. Hence from Tds=dhdpρ,

enthalpy diagram
Figure 1. Enthalpy vs. Entropy diagram for stage flow in turbine

it is easy to see that for isentropic process Template:Math. Hence it can be implied R=ΔH (Rotor)ΔH (Stage) The same can be expressed mathematically as:[2]

R=3ss2sdh3ss1dhor3ss2sdp3ss1dp

Where 1 to 3ss in Figure 1 represents the isentropic process beginning from stator inlet at 1 to rotor outlet at 3. And 2 to 3s is the isentropic process from rotor inlet at 2 to rotor outlet at 3. The velocity triangle[2] (Figure 2.) for the flow process within the stage represents the change in fluid velocity as it flows first in the stator or the fixed blades and then through the rotor or the moving blades. Due to the change in velocities there is a corresponding pressure change.

velocity triangle relates the inlet and outlet velocities within the stator and rotor during flow in a stage
Figure 2. Velocity Triangle for fluid flow in turbine

Another useful definition used commonly uses stage velocities as:[2] h2h3=12(Vr32Vr22)+12(U22U32) is the enthalpy drop in the rotor and[2] h01h03=h02h03=(U2Vw2U1Vw1) is the total enthalpy drop. The degree of reaction is then expressed as[3] R=12(Vr32Vr22)+12(U22U32)U2Vw2U1Vw1

For axial machines U2=U1=U, then[3] R=Vr32Vr222U(Vw3+Vw2) The degree of reaction can also be written in terms of the geometry of the turbomachine as obtained by[2] R=Vf2U(tanβ3tanβ2) where Template:Math is the vane angle of rotor outlet and Template:Math is the vane angle of stator outlet. In practice Vf2U is substituted as Template:Mvar and (tanβ3tanβ2)[2] as tanβm giving R=ϕtanβm. The degree of reaction now depends only on Template:Mvar and tanβm which again depend on geometrical parameters Template:Math and Template:Math i.e. the vane angles of stator outlet and rotor outlet. Using the velocity triangles degree of reaction can be derived as:[3] R=12+Vf2U(tanβ3tanα2) This relation is again very useful when the rotor blade angle and rotor vane angle are defined for the given geometry.

Choice of reaction (R) and effect on efficiency

Figure 3. Influence of reaction on total-to-static efficiency with fixed value of stage loading factor

The Figure 3[4] alongside shows the variation of total-to-static efficiency at different blade loading coefficient with the degree of reaction. The governing equation is written as

R=1+ΔW2U2Cy2U

where ΔW2U2 is the stage loading factor. The diagram shows the optimization of total - to - static efficiency at a given stage loading factor, by a suitable choice of reaction. It is evident from the diagram that for a fixed stage loading factor that there is a relatively small change in total-to-static efficiency for a wide range of designs.

50% reaction

The degree of reaction contributes to the stage efficiency and thus used as a design parameter. Stages having 50% degree of reaction are used where the pressure drop is equally shared by the stator and the rotor for a turbine.

Figure 4. Velocity triangle for Degree of Reaction = 1/2 in a turbine

This reduces the tendency of boundary layer separation from the blade surface avoiding large stagnation pressure losses.

If R= Template:Frac then from the relation of degree of reaction,|Template:EquationRef| α2 = β3 and the velocity triangle (Figure 4.) is symmetric. The stage enthalpy gets equally distributed in the stage (Figure 5.) . In addition the whirl components are also the same at the inlet of rotor and diffuser.

Figure 5. Stage enthalpy diagram for degree of reaction = 1⁄2 in a turbine and pump.
Figure 6. Stage enthalpy for Reaction less than half

Reaction less than 50%

Stage having reaction less than half suggest that pressure drop or enthalpy drop in the rotor is less than the pressure drop in the stator for the turbine. The same follows for a pump or compressor as shown in Figure 6. From the relation for degree of reaction, |Template:EquationRef| α2 > β3.

Figure 7. Velocity triangle for reaction more than 50%.

Reaction more than 50%

Stage having reaction more than half suggest that pressure drop or enthalpy drop in the rotor is more than the pressure drop in the stator for the turbine. The same follows for a pump or compressor. From the relation for degree of reaction,|Template:EquationRef| α2 < β3 which is also shown in corresponding Figure 7.

Template:Clear

Reaction = zero

This is special case used for impulse turbine which suggest that entire pressure drop in the turbine is obtained in the stator. The stator performs a nozzle action converting pressure head to velocity head. It is difficult to achieve adiabatic expansion in the impulse stage, i.e. expansion only in the nozzle, due to irreversibility involved, in actual practice. Figure 8 shows the corresponding enthalpy drop for the reaction = 0 case.

Figure 8. Stage enthalpy for degree of reaction =0 in a turbine

References

Template:Reflist

Further reading and works referred to

  • Gopalakrishnan, G. and Prithvi Raj, D., A Treatise on Turbomachines, Scitech, Chennai, India, 2012
  • Template:Cite book
  • Shepherd, D.G., Principles of Turbomachinery, Ninth Printing, Macmillan, 1969
  • Wisclicenus, G.F., Fluid Mechanics of Turbomachinery, McGraw-Hill, New York, 1947
  • Thomson, W.R., Preliminary Design of Gas Turbines, Emmott and CO. Ltd., London, 1963
  • Traupel, W., Thermische Turbomachinen, 3rd Edn, Springer Verlag, Berlin, 1978
  • Ainley, D. G. and Mathieson, G. C. R. (1951). A method of performance estimation for axial flow turbines. ARC R. and M.
  • Dunham, J. and Panton, J. (1973). Experiments on the design of a small axial turbine. Conference Publication 3, Instn. Mech. Engrs.
  • Horlock, J. H. (1960). Losses and efficiencies in axial-flow turbines. Int. J. Mech. Sci.,
  • Kim, T. H., Takao, M., Setoguchi, T., Kaneko, K. and Inoue, M. (2001). Performance comparison of turbines for wave power conversion. Int. J. Therm. Sci.,
  • http://www.physicsforums.com/archive/index.php/t-243219.html
  • https://www.scribd.com/doc/55453233/18/Degree-of-reaction Template:Webarchive
  1. Peng, William W., Fundamentals of turbomachinery, John Wiley, 2008
  2. 2.0 2.1 2.2 2.3 2.4 2.5 S.M, Yahya, Turbines, Compressors and Fans, 4th ed. McGraw,2011
  3. 3.0 3.1 3.2 Dixon, S. L., Fluid Mechanics and Thermodynamics of Turbo-machinery, 5th ed. Elsevier,2011.
  4. Shapiro, A. H., Soderberg, C. R., Stenning, A. H., Taylor, E. S. and Horlock, J. H. (1957). Notes on Turbomachinery. Department of Mechanical Engineering, Massachusetts Institute of Technology.