Template:Short description The total harmonic distortion (THD or THDi) is a measurement of the harmonic distortion present in a signal and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. Distortion factor, a closely related term, is sometimes used as a synonym.

In audio systems, lower distortion means that the components in a loudspeaker, amplifier or microphone or other equipment produce a more accurate reproduction of an audio recording.

In radio communications, devices with lower THD tend to produce less unintentional interference with other electronic devices. Since harmonic distortion can potentially widen the frequency spectrum of the output emissions from a device by adding signals at multiples of the input frequency, devices with high THD are less suitable in applications such as spectrum sharing and spectrum sensing.[1]

In power systems, lower THD implies lower peak currents, less heating, lower electromagnetic emissions, and less core loss in motors.[2] It is a key metric in the stability and quality of the U.S. electrical grid.[3] IEEE Standard 519-2022 covers the recommended practice and requirements for harmonic control in electric power systems.[4]

Definitions and examples

To understand a system with an input and an output, such as an audio amplifier, we start with an ideal system where the transfer function is linear and time-invariant. When a sinusoidal signal of frequency ω passes through a non-ideal, non-linear device, additional content is added at multiples (harmonics) of the original frequency. THD is a measure of that additional signal content not present in the input signal.

When the main performance criterion is the "purity" of the original sine wave (in other words, the contribution of the original frequency with respect to its harmonics), the measurement is most commonly defined as the ratio of the RMS amplitude of a set of higher harmonic frequencies to the RMS amplitude of the first harmonic, or fundamental frequency[1][2][5][6][7][8][9][10]

THDF=V22+V32+V42+V1,

where Vn is the RMS value of the nth harmonic voltage, and V1 is the RMS value of the fundamental component.

In practice, the THDF is commonly used in audio distortion specifications (percentage THD); however, THD is a non-standardized specification, and the results between manufacturers are not easily comparable. Since individual harmonic amplitudes are measured, it is required that the manufacturer disclose the test signal frequency range, level and gain conditions, and number of measurements taken. It is possible to measure the full 20 Hz–20 kHz range using a sweep (though distortion for a fundamental above 10 kHz is inaudible).

Measurements for calculating the THD are made at the output of a device under specified conditions. The THD is usually expressed in percent or in dB relative to the fundamental as distortion attenuation.

A variant definition uses the fundamental plus harmonics as the reference:[5][11][12]

THDR=V22+V32+V42+V12+V22+V32+=THDF1+THDF2.

These can be distinguished as THDF (for "fundamental"), and THDR (for "root mean square").[13][14] THDR cannot exceed 100%. At low distortion levels, the difference between the two calculation methods is negligible. For instance, a signal with THDF of 10% has a very similar THDR of 9.95%. However, at higher distortion levels the discrepancy becomes large. For instance, a signal with THDF 266% has a THDR of 94%.[5] A pure square wave with infinite harmonics has THDF of 48.3%[1][15][16] and THDR of 43.5%.[17][18]

Some use the term "distortion factor" as a synonym for THDR,[19] while others use it as a synonym for THDF.[20]

The International Electrotechnical Commission (IEC) also defines another term total harmonic factor for the "ratio of the RMS value of the harmonic content of an alternating quantity to the RMS value of the quantity" using a different equation.[21]

THD+N

THD+N means total harmonic distortion plus noise. This measurement is much more common and more comparable between devices. It is usually measured by inputting a sine wave, notch-filtering the output, and comparing the ratio between the output signal with and without the sine wave:[22]

THD+N=n=2harmonics+noisefundamental.

Like the THD measurement, this is a ratio of RMS amplitudes[8][23] and can be measured as THDF (bandpassed or calculated fundamental as the denominator) or, more commonly, as THDR (total distorted signal as the denominator).[24]

A meaningful measurement must include the bandwidth of measurement. This measurement includes effects from ground-loop power-line hum, high-frequency interference, intermodulation distortion between these tones and the fundamental, and so on, in addition to harmonic distortion. For psychoacoustic measurements, a weighting curve is applied such as A-weighting or ITU-R BS.468, which is intended to accentuate what is most audible to the human ear, contributing to a more accurate measurement. A-weighting is a rough way to estimate the frequency sensitivity of every persons' ears, as it does not take into account the non-linear behavior of the ear.[25] The loudness model proposed by Zwicker includes these complexities. The model is described in the German standard DIN45631[26]

For a given input frequency and amplitude, THD+N is reciprocal to SINAD, provided that both measurements are made over the same bandwidth.

Measurement

The distortion of a waveform relative to a pure sinewave can be measured either by using a THD analyzer to analyse the output wave into its constituent harmonics and noting the amplitude of each relative to the fundamental; or by cancelling out the fundamental with a notch filter and measuring the remaining signal, which will be total aggregate harmonic distortion plus noise.

Given a sinewave generator of very low inherent distortion, it can be used as input to amplification equipment, whose distortion at different frequencies and signal levels can be measured by examining the output waveform.

There is electronic equipment both to generate sinewaves and to measure distortion; but a general-purpose digital computer equipped with a sound card can carry out harmonic analysis with suitable software. Different software can be used to generate sinewaves, but the inherent distortion may be too high for measurement of very low-distortion amplifiers.

Interpretation

For many purposes, different types of harmonics are not equivalent. For instance, crossover distortion at a given THD is much more audible than clipping distortion at the same THD, since the harmonics produced by crossover distortion are nearly as strong at higher-frequency harmonics, such as 10× to 20× the fundamental, as they are at lower-frequency harmonics like 3× or 5× the fundamental. Those harmonics appearing far away in frequency from a fundamental (desired signal) are not as easily masked by that fundamental.[27] In contrast, at the onset of clipping, harmonics first appear at low-order frequencies and gradually start to occupy higher-frequency harmonics. A single THD number is therefore inadequate to specify audibility and must be interpreted with care. Taking THD measurements at different output levels would expose whether the distortion is clipping (which decreases with an decreasing level) or crossover (which stays constant with varying output level, and thus is a greater percentage of the sound produced at low volumes).

THD is a summation of a number of harmonics equally weighted, even though research performed decades ago identifies that lower-order harmonics are harder to hear at the same level, compared with higher-order ones. In addition, even-order harmonics are said to be generally harder to hear than odd-order.[28] A number of methods have been developed to estimate the actual audibility of THD, used to quantify crossover distortion or loudspeaker rub and buzz, such as "high-order harmonic distortion" (HOHD) or "higher harmonic distortion" (HHD) which measures only the 10th and higher harmonics, or metrics that apply psychoacoustic loudness curves to the residual.[29][30]

Examples

For many standard signals, the above criterion may be calculated analytically in a closed form.[1] For example, a pure square wave has THDF equal to

THDF=π2810.483=48.3%.

The sawtooth signal possesses

THDF=π2610.803=80.3%.

The pure symmetrical triangle wave has

THDF=π49610.121=12.1%.

For the rectangular pulse train with the duty cycle μ (called sometimes the cyclic ratio), the THDF has the form

THDF(μ)=μ(1μ)π22sin2πμ1,0<μ<1,

and logically, reaches the minimum (≈0.483) when the signal becomes symmetrical μ = 0.5, i.e. the pure square wave.[1] Appropriate filtering of these signals may drastically reduce the resulting THD. For instance, the pure square wave filtered by the Butterworth low-pass filter of the second order (with the cutoff frequency set equal to the fundamental frequency) has THDF of 5.3%, while the same signal filtered by the fourth-order filter has THDF of 0.6%.[1] However, analytic computation of the THDF for complicated waveforms and filters often represents a difficult task, and the resulting expressions may be quite laborious to obtain. For example, the closed-form expression for the THDF of the sawtooth wave filtered by the first-order Butterworth low-pass filter is simply

THDF=π23πcothπ0.370=37.0%,

while that for the same signal filtered by the second-order Butterworth filter is given by a rather cumbersome formula[1]

THDF=πcotπ2coth2π2cot2π2cothπ2cotπ2cothπ22(cot2π2+coth2π2)+π2310.181=18.1%.

Yet, the closed-form expression for the THDF of the pulse train filtered by the pth-order Butterworth low-pass filter is even more complicated and has the following form:[1]

THDF(μ,p)=cscπμμ(1μ)π2sin2πμπ2s=12pcotπzszs2l=1ls2p1zszl+π2Res=12peiπzs(2μ1)zs2sinπzsl=1ls2p1zszl,

where μ is the duty cycle, 0 < μ < 1, and

zlexpiπ(2l1)2p,l=1,2,,2p.

See also

References

Template:Reflist

  1. 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 Template:Cite journal
  2. 2.0 2.1 Template:Cite web
  3. Template:Cite web
  4. Template:Cite journal
  5. 5.0 5.1 5.2 Template:Cite journal
  6. Template:Cite book
  7. Template:Cite web
  8. 8.0 8.1 Template:Cite web
  9. IEEE 519 and other standards (draft): "distortion factor: The ratio of the root-mean-square of the harmonic content to the root-mean-square value of the fundamental quantity, often expressed as a percent of the fundamental. Also referred to as total harmonic distortion."
  10. Section 11: Power Quality Considerations. Bill Brown, P.E., Square D Engineering Services.
  11. Template:Cite journal
  12. Template:Cite book
  13. AEMC 605 User Manual. "THDf: Total harmonic distortion with respect to the fundamental. THDr: Total harmonic distortion with respect to the true RMS value of the signal."
  14. Template:Cite web
  15. Template:Cite web
  16. Template:Cite book
  17. Template:Cite web
  18. Template:Cite web
  19. Template:Cite web
  20. Template:Cite web
  21. Template:Cite web
  22. Template:Cite web
  23. Op Amp Distortion: HD, THD, THD + N, IMD, SFDR, MTPR.
  24. Introduction to the Basic Six Audio Tests: "Since the sum of the distortion products will always be less than the total signal, the THD+N ratio will always be a negative decibel value, or a percent value less than 100%."
  25. Template:Cite book
  26. The loudness model proposed by Zwicker includes these complexities. The model is described in the German standard DIN45631.
  27. Template:Cite web
  28. Template:Cite web
  29. Template:Cite web
  30. Template:Cite web